Product Details
- Product type: Display membrane switch assembly replacement
- Brand: Hayward
- Part number: GLX-AR-PRO-MEM
- Compatible system type: Select Hayward AQR-PRO Goldline Aqua Rite Pro salt chlorine generators
- Use: Replacement membrane display/control interface for compatible Aqua Rite Pro systems
- Best use case: Replacing a damaged or non-responsive membrane panel while keeping the existing compatible control system
- Package contents: Display membrane switch assembly only, unless faceplate, adhesive backing, wiring ribbon, mounting parts, or instructions are specifically listed
- Installation requirement: Power must be fully off before opening or servicing the control area
Compatibility and Buyer Check
Before ordering, confirm that your Aqua Rite Pro system manual or existing part label calls for GLX-AR-PRO-MEM. This part should be matched by part number, system model, display layout, and connection style, not by image alone.
If your issue is with a standard Aqua Rite display instead of an Aqua Rite Pro membrane assembly, review the Hayward GLX-PCB-DSP Aqua Rite PCB display before ordering. If the display problem may be caused by the main board, compare the Hayward GLX-PCB-RITE main circuit board before replacing only the membrane switch.
If your system is part of a chemistry automation setup, compare it with the Hayward Goldline HL-CHEM Sense and Dispense system before choosing related display or control parts.
What This Membrane Switch Assembly Does
The membrane switch assembly is the user-facing control surface on compatible Hayward Aqua Rite Pro systems. It allows you to press buttons, access settings, and interact with the control panel during normal salt chlorine generator operation.
Replacing the membrane assembly may help when the buttons are damaged, sticking, faded, cracked, or not responding correctly. It will not fix every control issue. A blank screen, no power, error codes, incorrect salt readings, or low chlorine output may also come from the main PCB, transformer, fuse area, wiring, salt cell, flow switch, or water chemistry.
Before You Order
Check these details before purchasing:
- Confirm the exact part number GLX-AR-PRO-MEM.
- Verify that your system is a compatible Hayward AQR-PRO Goldline Aqua Rite Pro model.
- Compare the button layout, membrane shape, wiring connection, and panel style with your existing part.
- Inspect the control box for moisture, corrosion, burned wiring, or loose terminals.
- Confirm whether the issue is the membrane switch, display board, main board, power supply, or wiring.
- If the unit has power problems, check the Hayward GLX-XFMR transformer replacement and Hayward GLX-FUSE-20 fuse holder replacement kit before assuming the membrane is the only failed part.
- Do not order this part for AquaTrol, OnCommand, or standard Aqua Rite systems unless the service manual confirms compatibility.
Installation and Safety Notes
Turn off power at the breaker before opening the control box or touching any electrical part. Do not work on pool electrical equipment while the system is powered.
Before removing the old membrane switch assembly, take clear photos of the wiring, connector position, display layout, and panel placement. Remove the old part carefully and clean the mounting surface before installing the replacement. Do not force the ribbon connector or reuse damaged wiring.
After installation, close the control area properly, restore power, and confirm that the buttons, display response, system menu, and connected salt system functions are working normally.
Maintenance and Troubleshooting Tips
To help protect the replacement membrane switch assembly:
- Keep the control box closed and protected from moisture.
- Avoid pressing buttons with sharp tools or excessive force.
- Inspect the display area for water intrusion or corrosion during service.
- Check fuse, transformer, and board issues before replacing multiple display parts.
- Keep wiring secure and away from sharp edges.